{"product_id":"airmar-smartflex-diesel-flow-meter-50-300-lph-dual-chamber-alloy-housing-threaded-connections-dfm-300-da","title":"Airmar SmartFlex Diesel Flow Meter, 50-300 LPH, Dual-Chamber, Alloy Housing, Threaded Connections - DFM-300-DA","description":"\u003ch3\u003eAirmar SmartFlex Diesel Flow Meter, 50-300 LPH, Dual-Chamber, Alloy Housing, Threaded Connections - DFM-300-DA\u003c\/h3\u003e\n\u003cp class=\"TypographyStyle-sc-11lquxl fNvNrO\"\u003e\u003cspan class=\"TypographyStyle-sc-11lquxl iEudhm\"\u003ePart #\u003c\/span\u003eDFM-300-DA\u003c\/p\u003e\n\u003cp class=\"TypographyStyle-sc-11lquxl fNvNrO\"\u003e\u003cspan class=\"TypographyStyle-sc-11lquxl iEudhm\"\u003eMFG #\u003c\/span\u003eDFM-300-DA\u003c\/p\u003e\n\u003cp class=\"TypographyStyle-sc-11lquxl ldRYJK\"\u003e\u003cstrong\u003eSmartFlex Dual-Chamber Diesel Fuel Flow Meter\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"TypographyStyle-sc-11lquxl ldRYJK\"\u003eThe SmartFlex\u003csup\u003e™\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003edual-chamber flow meters are designed for fuel consumption measurement of diesel engine systems with flow rates up to 600 L\/h. The flow meter measures fuel consumption in each line and computes the difference between supply and return. SmartFlex DFMs output NMEA2000\u003csup\u003e®\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003eto a T1 or T2 SmartBoat or SmartFlex Module*, for display on multi-function displays or Signal K interfaces.\u003c\/p\u003e\n\u003cp class=\"TypographyStyle-sc-11lquxl ldRYJK\"\u003e\u003cstrong\u003eDifferential measurement of fuel consumption\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"TypographyStyle-sc-11lquxl ldRYJK\"\u003eSmartFlex dual-chamber DFMs have two measuring chambers for supply and return fuel lines. The flow meter measures fuel consumption in each line and computes the difference between supply and return.\u003c\/p\u003e\n\u003cp class=\"TypographyStyle-sc-11lquxl ldRYJK\"\u003e\u003cstrong\u003eBuilt-in battery\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"TypographyStyle-sc-11lquxl ldRYJK\"\u003eIn case of the absence of an external power source, from the on-board network for example, the SmartFlex DFM keeps registering data to the internal memory. When external power is restored, all accumulated data will be transferred to the on-board monitoring terminal.\u003c\/p\u003e\n\u003cp class=\"TypographyStyle-sc-11lquxl ldRYJK\"\u003e\u003cstrong\u003e*SmartFlex DFM must be connected to a SmartBoat\u003c\/strong\u003e\u003csup\u003e\u003cstrong\u003e®\u003c\/strong\u003e\u003c\/sup\u003e\u003cstrong\u003e\u003cspan\u003e \u003c\/span\u003eor SmartFlex T1 or T2 CES module.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"TypographyStyle-sc-11lquxl ldRYJK\"\u003eDFM models provide data for fuel consumption including:\u003c\/p\u003e\n\u003cul class=\"UnorderedListStyle-sc-1koui9a koGePn\"\u003e\n\u003cli class=\"ListItemStyle-sc-1yqofwy gqiGZs\"\u003eInstant fuel consumption, L\/H\u003c\/li\u003e\n\u003cli class=\"ListItemStyle-sc-1yqofwy gqiGZs\"\u003eHourly fuel consumption in “Forward” line\u003c\/li\u003e\n\u003cli class=\"ListItemStyle-sc-1yqofwy gqiGZs\"\u003eHourly fuel consumption in “Return” line\u003c\/li\u003e\n\u003cli class=\"ListItemStyle-sc-1yqofwy gqiGZs\"\u003eTotal fuel consumption, L\u003c\/li\u003e\n\u003cli class=\"ListItemStyle-sc-1yqofwy gqiGZs\"\u003eTotal fuel consumption in “Idling” mode of engine operation\u003c\/li\u003e\n\u003cli class=\"ListItemStyle-sc-1yqofwy gqiGZs\"\u003eTotal fuel consumption in “Optimal” mode of engine operation\u003c\/li\u003e\n\u003cli class=\"ListItemStyle-sc-1yqofwy gqiGZs\"\u003eTotal fuel consumption in “Overload” mode of engine operation\u003c\/li\u003e\n\u003cli class=\"ListItemStyle-sc-1yqofwy gqiGZs\"\u003eTotal fuel consumption in “Negative” mode of flow meter operation (return exceeds supply)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFeatures\u003c\/p\u003e\n\u003cul class=\"UnorderedListStyle--1koui9a ksyVRL\"\u003e\n\u003cli class=\"ListItemStyle-sc-1yqofwy gqiGZs\"\u003eLower overall cost due to differential sensor capabilities\u003c\/li\u003e\n\u003cli class=\"ListItemStyle-sc-1yqofwy gqiGZs\"\u003eEase of installation with optional accessory kit\u003c\/li\u003e\n\u003cli class=\"ListItemStyle-sc-1yqofwy gqiGZs\"\u003eAutomatic Temperature compensation\u003c\/li\u003e\n\u003cli class=\"ListItemStyle-sc-1yqofwy gqiGZs\"\u003eSimple set up using the SmartFlex View software embedded in the Airmar SmartFlex or SmartBoat module\u003c\/li\u003e\n\u003cli class=\"ListItemStyle-sc-1yqofwy gqiGZs\"\u003eFuel never comes in contact with gears or other parts that might clog or corrode\u003c\/li\u003e\n\u003cli class=\"ListItemStyle-sc-1yqofwy gqiGZs\"\u003eThe sensor is digital – specialized wiring isn’t required – plug and play to the SmartFlex or SmartBoat Module for data delivery to the display.\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eSpecifications\u003c\/p\u003e\n\u003cdiv class=\"sc-bczRLJ kEeNDb\"\u003e\n\u003cdiv class=\"sc-bczRLJ kEeNDb\"\u003e\n\u003cspan class=\"TypographyStyle-sc-11lquxl hXwBBx\"\u003eBrand: \u003c\/span\u003e\u003cspan class=\"TypographyStyle-sc-11lquxl bLpGkr\"\u003eAirmar Technology\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"sc-bczRLJ kEeNDb\"\u003e\n\u003cspan class=\"TypographyStyle-sc-11lquxl hXwBBx\"\u003eConnecting Thread: \u003c\/span\u003e\u003cspan class=\"TypographyStyle-sc-11lquxl bLpGkr\"\u003eM14 x 1.5\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"sc-bczRLJ kEeNDb\"\u003e\n\u003cspan class=\"TypographyStyle-sc-11lquxl hXwBBx\"\u003eConnection Type: \u003c\/span\u003e\u003cspan class=\"TypographyStyle-sc-11lquxl bLpGkr\"\u003eThreaded\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"sc-bczRLJ kEeNDb\"\u003e\n\u003cspan class=\"TypographyStyle-sc-11lquxl hXwBBx\"\u003eFlow Capacity: \u003c\/span\u003e\u003cspan class=\"TypographyStyle-sc-11lquxl bLpGkr\"\u003e50 – 300 LPH ±1% (13 – 79 GPH ±1%)\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"sc-bczRLJ kEeNDb\"\u003e\n\u003cspan class=\"TypographyStyle-sc-11lquxl hXwBBx\"\u003eFuel Type: \u003c\/span\u003e\u003cspan class=\"TypographyStyle-sc-11lquxl bLpGkr\"\u003eDiesel\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"sc-bczRLJ kEeNDb\"\u003e\n\u003cspan class=\"TypographyStyle-sc-11lquxl hXwBBx\"\u003eLCD Display: \u003c\/span\u003e\u003cspan class=\"TypographyStyle-sc-11lquxl bLpGkr\"\u003eNo\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"sc-bczRLJ kEeNDb\"\u003e\n\u003cspan class=\"TypographyStyle-sc-11lquxl hXwBBx\"\u003eMaterial: \u003c\/span\u003e\u003cspan class=\"TypographyStyle-sc-11lquxl bLpGkr\"\u003eAlloy\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"sc-bczRLJ kEeNDb\"\u003e\n\u003cspan class=\"TypographyStyle-sc-11lquxl hXwBBx\"\u003eNumber of Chambers: \u003c\/span\u003e\u003cspan class=\"TypographyStyle-sc-11lquxl bLpGkr\"\u003eDual\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"sc-bczRLJ kEeNDb\"\u003e\n\u003cspan class=\"TypographyStyle-sc-11lquxl hXwBBx\"\u003eNumber of Engines: \u003c\/span\u003e\u003cspan class=\"TypographyStyle-sc-11lquxl bLpGkr\"\u003eMultiple\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"sc-bczRLJ kEeNDb\"\u003e\n\u003cspan class=\"TypographyStyle-sc-11lquxl bLpGkr\"\u003e\u003c\/span\u003e\u003cbr\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"sc-bczRLJ kEeNDb\"\u003e\n\u003cdiv class=\"GridItemStyle-sc-1uambol bVkglf\"\u003e\n\u003cdiv class=\"sc-bczRLJ gvPJf\"\u003e\u003ca href=\"https:\/\/www.airmarweb.com\/uploads\/brochures\/Diesel-Flow-Meter-SpecSheet.pdf\" target=\"_blank\" rel=\"noopener\"\u003e\u003cspan class=\"TypographyStyle-sc-11lquxl iLQiPx\"\u003eSpecification\u003c\/span\u003e\u003cspan class=\"TypographyStyle-sc-11lquxl iLQiPx\"\u003eDiesel Flow Meter SpecSheet\u003c\/span\u003e\u003c\/a\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"GridItemStyle-sc-1uambol bVkglf\"\u003e\n\u003ca class=\"StyledButton-sc-1y32st kUXsUo StyledClickable-sc-49spz0 dOMjIe\" href=\"https:\/\/assets-7484b3de52.cdn.insitecloud.net\/6c5e5a66925871e\/D-21349-rev2.pdf\" tabindex=\"0\"\u003e\n\u003cdiv height=\"60px\" width=\"60px\" class=\"LazyImageStyle-sc-15g8d3a gVnWWM\"\u003e\n\u003cbr\u003e\u003cspan class=\"LazyImage-Placeholder\"\u003e\u003c\/span\u003e\n\u003c\/div\u003e\n\u003c\/a\u003e\n\u003cdiv class=\"sc-bczRLJ gvPJf\"\u003e\u003ca href=\"https:\/\/assets-7484b3de52.cdn.insitecloud.net\/6c5e5a66925871e\/D-21349-rev2.pdf\" target=\"_blank\" rel=\"noopener\"\u003e\u003cspan class=\"TypographyStyle-sc-11lquxl iLQiPx\"\u003eUser Guide\u003c\/span\u003e\u003cspan class=\"TypographyStyle-sc-11lquxl iLQiPx\"\u003eDiesel Flow Meter Installation and User Manual\u003c\/span\u003e\u003c\/a\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"sc-bczRLJ kEeNDb\"\u003e\n\u003cspan class=\"TypographyStyle--11lquxl gtqutn\"\u003e\u003c\/span\u003e\u003cbr\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"sc-bczRLJ kEeNDb\"\u003e\n\u003cspan class=\"TypographyStyle--11lquxl gtqutn\"\u003e\u003c\/span\u003e\u003cbr\u003e\n\u003c\/div\u003e","brand":"Airmar","offers":[{"title":"Default Title","offer_id":47575255351458,"sku":null,"price":999.95,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0586\/1405\/5074\/files\/d3e1e2bcfcd8037_lg.png?v=1787676756","url":"https:\/\/navstore.com\/products\/airmar-smartflex-diesel-flow-meter-50-300-lph-dual-chamber-alloy-housing-threaded-connections-dfm-300-da","provider":"NavStore","version":"1.0","type":"link"}